Pepperl+Fuchs, KFD2-STC4-EX1,

  • Type: 1-channel isolated barrier (SMART Transmitter Power Supply)
  • Power Supply: 24 V DC (Power Rail)
  • Input:
    • 2-wire and 3-wire SMART transmitters
    • 2-wire SMART current sources
  • Output: 0/4 mA … 20 mA
  • Test Points: Terminals with test points
  • Safety Integrity Level (SIL): SIL 2 (according to IEC/EN 61508)
  • HART Communication: Yes
  • Housing Width: 20 mm
  • Channels: 1-channel
  • Rated Voltage: 20 … 35 V DC
  • Field Device Compatibility:
    • 2-wire transmitter
    • 3-wire transmitter
    • Current source

SKU:

Price:

$499,00

Pepperl+Fuchs KFD2-STC4-EX1 (P.N. 122580) Technical Specifications

1. General Information

  • Manufacturer: Pepperl+Fuchs

  • Model: KFD2-STC4-EX1

  • Part Number: 122580

  • Type: Signal conditioner/isolator with intrinsic safety (Ex) protection

  • Primary Use: Signal conversion and isolation for temperature sensors (RTD/thermocouple) in hazardous areas

2. Certifications & Approvals

  • Hazardous Area Certifications:

    • ATEX/IECEx: Ex ia IIC T6 Ga (Gas) / Ex ia IIIC T85°C Da (Dust)

    • FM Approval: Class I, II, III, Division 1

    • CSA: Class I, Zone 0

  • Safety Standards: IEC 61508 (SIL 2/3 capable)

3. Electrical Characteristics

  • Input Types:

    • RTD: Pt100, Pt200, Pt500, Ni100, Cu10

    • Thermocouples: Types J, K, S, R, T, B, N, E

    • Voltage: 0-10V, 0-5V

    • Current: 0-20mA, 4-20mA

  • Output Signal: 4-20mA (active/passive configurable)

  • Power Supply: 20-30V DC (24V typical)

  • Isolation: 1500V AC (input/output/power)

  • Accuracy: ±0.1% of span (RTD/thermocouple)

4. Environmental Specifications

  • Operating Temperature: -20°C to +60°C

  • Storage Temperature: -40°C to +85°C

  • Humidity: 0-95% non-condensing

  • Protection Rating: IP20 (for panel mounting)

5. Mechanical Specifications

  • Housing Material: Polycarbonate

  • Dimensions: 17.5 x 116 x 121.5 mm (WxHxD)

  • Mounting: DIN rail (35mm)

  • Weight: Approx. 150g

6. Configuration & Indicators

  • Configuration: DIP switches for input type selection

  • LED Indicators:

    • Green: Power ON

    • Yellow: Signal transmission

    • Red: Fault condition

7. Ordering Information

  • Lead Time: Typically 2-4 weeks (standard)

  • Alternative Models:

    • KFD2-STC4-EX2 (P.N. 132952) – Enhanced version

    • KFD2-STC4-EX1.W (P.N. 122581) – Special variant

8. Typical Applications

  • Temperature monitoring in hazardous areas

  • Process control in oil & gas facilities

  • Chemical and pharmaceutical plants

  • Power generation systems

Pepperl+Fuchs, KFD2-STC4-EX1,

  • Type: 1-channel isolated barrier (SMART Transmitter Power Supply)
  • Power Supply: 24 V DC (Power Rail)
  • Input:
    • 2-wire and 3-wire SMART transmitters
    • 2-wire SMART current sources
  • Output: 0/4 mA … 20 mA
  • Test Points: Terminals with test points
  • Safety Integrity Level (SIL): SIL 2 (according to IEC/EN 61508)
  • HART Communication: Yes
  • Housing Width: 20 mm
  • Channels: 1-channel
  • Rated Voltage: 20 … 35 V DC
  • Field Device Compatibility:
    • 2-wire transmitter
    • 3-wire transmitter
    • Current source

DATASHEET:Pepperl+Fuchs MODEL KFD2-STC4-EX1